Technical Data

 

Supply

Voltage24 Vdc nom (18 to 30 Vdc), reverse polarity protected
Current Consumption90 mA @ 24 Vdc with 20 mA out, typical.
Power Dissipation1.35 W @ 24 Vdc with 20 mA out, typical.

Input

Type4 to 20 mA (separately powered input, voltage drop ≤ 0.5 V) or 4 to 20 mA (2 wires Tx current limited ≈ 25 mA), reading range 0 to 24 mA.
Transmitter line voltage15.0 V typical, 14.5 V minimum, @ 20 mA.

Output

Type4 to 20 mA, on max. 550 Ω load in source mode (typical 12 V compliance); V min. 8 V @ 0 Ω load V max. 30 V in sink mode, current limited ≈ 25 mA or 1 to 5 V on internal 250 Ω shunt. Output current duplication available (D5014D).
Response time5 ms (0 to 100 % step change).

Performance

Ref. Conditions24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature.
Calibration accuracy≤ ± 0.1 % FSR.
Linearity accuracy≤ ± 0.05 % FSR.
Temp. influence≤ ± 0.01 % FSR on zero/span for a 1 °C change.

Isolation

Test VoltageI.S. In/Out 2.5 kV; I.S. In/Supply 2.5 kV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V.

Environmental conditions

Operating temperaturetemperature limits –40 to +70 °C.
Storage temperaturetemperature limits –45 to +80 °C.

Safety description

EquipmentAssociated apparatus and non-sparking electrical equipment.
Safety parametersUo = 25.9 V, Io = 92 mA, Po = 594 mW at terminals 7-8, 9-10. Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals 8-11, 10-12. Ui = 30 V, Ii = 128 mA, Ci = 0 nF, Li = 0 nH at terminals 8-11, 10-12. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.

Mounting

TypeDIN-Rail 35 mm, with or without Power Bus or on custom Term. Board.
Weightabout 155 g
Connectionby polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).
DimensionsWidth 12.5 mm, Depth 123 mm, Height 120 mm.

Zarejestruj się i korzystaj z własnych warunków handlowych

OPIS produktu poz 1 w konfiuratorze

The Repeater Power Supply D5014 module is a high integrity analog input interface suitable for applications requiring SIL 3 level in safety related systems for high risk industries. It provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA, active or passive, transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The module supports output current duplication and it allows bi-directional communication signals, for HART® devices.

FEATURES

  • SIL 3 / SC 3
  • Input from Zone 0/Div. 1
  • Installation in Zone 2/Div. 2
  • 2 fully independent channels
  • 4-20 mA Active-Passive Input, Source-Sink Output
  • Output current duplication available
  • HART® compatible
  • Input and Output short circuit proof
  • In-field programmability by DIP Switch
  • High Accuracy
  • Three port isolation, Input/Output/Supply
  • High Density, two channels per unit

NOWWA za kląłdka nr 1

W zakładce nr 1

Technical Data

 

Supply

Voltage24 Vdc nom (18 to 30 Vdc), reverse polarity protected
Current Consumption90 mA @ 24 Vdc with 20 mA out, typical.
Power Dissipation1.35 W @ 24 Vdc with 20 mA out, typical.

Input

Type4 to 20 mA (separately powered input, voltage drop ≤ 0.5 V) or 4 to 20 mA (2 wires Tx current limited ≈ 25 mA), reading range 0 to 24 mA.
Transmitter line voltage15.0 V typical, 14.5 V minimum, @ 20 mA.

Output

Type4 to 20 mA, on max. 550 Ω load in source mode (typical 12 V compliance); V min. 8 V @ 0 Ω load V max. 30 V in sink mode, current limited ≈ 25 mA or 1 to 5 V on internal 250 Ω shunt. Output current duplication available (D5014D).
Response time5 ms (0 to 100 % step change).

Performance

Ref. Conditions24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature.
Calibration accuracy≤ ± 0.1 % FSR.
Linearity accuracy≤ ± 0.05 % FSR.
Temp. influence≤ ± 0.01 % FSR on zero/span for a 1 °C change.

Isolation

Test VoltageI.S. In/Out 2.5 kV; I.S. In/Supply 2.5 kV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V.

Environmental conditions

Operating temperaturetemperature limits –40 to +70 °C.
Storage temperaturetemperature limits –45 to +80 °C.

Safety description

EquipmentAssociated apparatus and non-sparking electrical equipment.
Safety parametersUo = 25.9 V, Io = 92 mA, Po = 594 mW at terminals 7-8, 9-10. Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals 8-11, 10-12. Ui = 30 V, Ii = 128 mA, Ci = 0 nF, Li = 0 nH at terminals 8-11, 10-12. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.

Mounting

TypeDIN-Rail 35 mm, with or without Power Bus or on custom Term. Board.
Weightabout 155 g
Connectionby polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).
DimensionsWidth 12.5 mm, Depth 123 mm, Height 120 mm.

NOWWA za kląłdka nr 12

Może Cię zainteresuje

Dwyer Manometr Magnehelic® Serii 2000 służy do pomiaru niskich ciśnień z dokładnością 2%

Dostawa: 2-4 tygodnie
Wycena indywidualna

Seria Photohelic serii 3000MR/3000MRS Sygnalizator manometr różnicy ciśnień /miernik

Dostawa: 2-4 tygodnie
Wycena indywidualna

Mierniki różnicy ciśnień Magnehelic® serii AT-2000 z certyfikatem ATEX/IECEx

Dostawa: 2-4 tygodnie
Wycena indywidualna

Ostatnio oglądane

Producent: BD Sensors
Dostawa: 3-4 tygodnie
Wycena indywidualna

High Pressure OEM Valves Series 6140, 6180, 6900, 6940

Dostawa: 6-10 tygodni
Cena od: € 0.01
      Prośba o wycenę
      Zapytanie o produkt
      Powielony grupowy D5014D D5014S I.S. SIL3 2/4-Wire HART® Transmitter Power Supply (Kopia)
      ×