{"id":20032,"date":"2024-10-08T02:35:21","date_gmt":"2024-10-08T00:35:21","guid":{"rendered":"https:\/\/trautomatyka.com.pl\/produkt\/ba327se-2-ex-ec\/"},"modified":"2025-09-04T12:10:30","modified_gmt":"2025-09-04T10:10:30","slug":"ba327se-ex-ec","status":"publish","type":"product","link":"https:\/\/trautomatyka.com.pl\/en\/product\/ba327se-ex-ec\/","title":{"rendered":"BA327SE Ex ec"},"content":{"rendered":"<table class=\"table table-striped table-borderless\">\n<thead>\n<tr>\n<th class=\"first_row_cell\">Model<\/th>\n<th class=\"ex_eb_cell\">BA307SE<\/th>\n<th class=\"ex_eb_cell\">BA327SE<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"first_row_cell\"><\/td>\n<td><\/td>\n<td>*<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\">Monta\u017c &amp; Obudowa<\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\">Panel<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\">Ochrona<\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\">Prz\u00f3d IP66, ty\u0142 IP20<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\">Wy\u015bwietlacz<\/td>\n<td class=\"ex_eb_cell\">4 cyfry 15 mm wysoko\u015bci<\/td>\n<td class=\"ex_eb_cell\">5 cyfr 12,7 mm wysoko\u015bci<br \/>\n+ wykres s\u0142upkowy<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\" colspan=\"3\"><strong>Certyfikaty<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\"><em>Mi\u0119dzynarodowy<\/em><br \/>\n<em>IECEx<\/em><\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\"><strong><em>Gaz &#8211; <\/em><\/strong>Ex ec ic IIC T5 Gc\u00a0 \u00a0<em>Bezpiecze\u0144stwo zwi\u0119kszone\u00a0Ex ec<\/em><br \/>\n<strong><em>Py\u0142 &#8211; <\/em><\/strong>Ex ic tc IIIC T80\u00b0C Dc\u00a0 \u00a0<em>Ochrona przez obudow\u0119\u00a0Ex tc<\/em><br \/>\n-40\u00b0C \u2264 Ta \u2264 +70\u00b0C<br \/>\nCert. nr IECEx ITS 22.0023X<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\"><em>Europa<\/em><br \/>\n<em>ATEX<\/em><\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\"><strong><em>Gaz &#8211; <\/em><\/strong>Grupa II Kategoria 3G Ex ec ic IIC T5 Gc\u00a0 \u00a0<em>Bezpiecze\u0144stwo zwi\u0119kszone\u00a0Ex ec<\/em><br \/>\n<strong><em>Py\u0142 &#8211; <\/em><\/strong>Grupa II Kategoria 3D Ex ic tc IIIC T80\u00b0C Dc\u00a0 \u00a0<em>Ochrona przez obudow\u0119\u00a0Ex tc<\/em><br \/>\n-40\u00b0C \u2264 Ta \u2264 +70\u00b0C<br \/>\nCert. nr ITS-1 22 ATEX 34494X R.O<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\"><em>Wielka Brytania<\/em><br \/>\n<em>UKEX<\/em><\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\"><strong><em>Gaz &#8211; <\/em><\/strong>Grupa II Kategoria 3G Ex ec ic IIC T5 Gc\u00a0 \u00a0<em>Bezpiecze\u0144stwo zwi\u0119kszone\u00a0Ex ec<\/em><br \/>\n<strong><em>Py\u0142 &#8211; <\/em><\/strong>Grupa II Kategoria 3D Ex ic tc IIIC T80\u00b0C Dc\u00a0 \u00a0<em>Ochrona przez obudow\u0119\u00a0Ex tc<\/em><br \/>\n-40\u00b0C \u2264 Ta \u2264 +70\u00b0C<br \/>\nCert. nr ITS 22 UKEX 0609X<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\"><em>USA ETL<\/em><\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\"><strong><em>Gaz &#8211;\u00a0<\/em><\/strong><span style=\"background-color: transparent;\">Klasa I Strefa 2 AEx ec ic IIC T5 Gc<\/span>\u00a0 \u00a0<em>Bezpiecze\u0144stwo zwi\u0119kszone\u00a0Ex ec<\/em><br \/>\n<strong><em>Py\u0142 &#8211;\u00a0<\/em><\/strong><span style=\"background-color: transparent;\">Strefa 22 AEx ic tc IIIC T85\u00baC Dc<\/span>\u00a0 \u00a0<em>Ochrona przez obudow\u0119\u00a0Ex tc<\/em><br \/>\n<span style=\"background-color: transparent;\">Klasa I Div 2 Grupy A, B, C, D<\/span><br \/>\n<span style=\"background-color: transparent;\"> Klasa II Div 2 Grupy F, G<\/span><br \/>\n<span style=\"background-color: transparent;\"> Klasa III Div 2<\/span><br \/>\n<span style=\"background-color: transparent;\"> -40\u00baC \u2264 Ta \u2264 +70\u00baC<\/span><br \/>\nUpowa\u017cnienie do oznaczenia 104724586LHD-001<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\"><em>Kanada cETL<\/em><\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\"><strong><em>Gaz &#8211;\u00a0<\/em><\/strong><span style=\"background-color: transparent;\">Ex ec ic IIC T5 Gc<\/span>\u00a0 \u00a0<em>Bezpiecze\u0144stwo zwi\u0119kszone\u00a0Ex ec<\/em><br \/>\n<strong><em>Py\u0142 &#8211;\u00a0<\/em><\/strong><span style=\"background-color: transparent;\">Ex ic tc IIIC T85\u00baC Dc<\/span>\u00a0 \u00a0<em>Ochrona przez obudow\u0119\u00a0Ex tc<\/em><br \/>\n<span style=\"background-color: transparent;\">Klasa I Div 2 Grupy A, B, C, D<\/span><br \/>\n<span style=\"background-color: transparent;\"> Klasa II Div 2 Grupy F, G<\/span><br \/>\n<span style=\"background-color: transparent;\"> Klasa III Div 2<\/span><br \/>\n<span style=\"background-color: transparent;\"> -40\u00baC \u2264 Ta \u2264 +70\u00baC<\/span><br \/>\nUpowa\u017cnienie do oznaczenia 104724586LHD-001<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\" colspan=\"3\"><strong>Opcje<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\"><em>Alarmy<\/em><\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\">Tak<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\"><em>Pod\u015bwietlenie, kt\u00f3re mo\u017ce by\u0107 zasilane przez p\u0119tl\u0119 lub <\/em><br \/>\n<em>osobne zasilanie<\/em><\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\">Tak<\/td>\n<\/tr>\n<tr>\n<td class=\"first_row_cell\"><em>Skala i etykieta\/aplikacja<\/em><br \/>\n<em>oznaczenie (bez op\u0142at)<\/em><\/td>\n<td class=\"ex_eb_cell\" colspan=\"2\">Tak<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p><strong>Funkcje:<\/strong><\/p>\n<ul>\n<li>Certyfikacja Ex ec i Ex tc eliminuje potrzeb\u0119 stosowania barier Zenera i izolator\u00f3w galwanicznych<\/li>\n<li>Du\u017ce, nieliniowe wy\u015bwietlacze, modele z:\n<ul>\n<li>5 cyfr: 12,7 mm wysoko\u015bci + wska\u017anik s\u0142upkowy<\/li>\n<\/ul>\n<\/li>\n<li>Wytrzyma\u0142e obudowy ze stali nierdzewnej do stosowania w panelach Ex e, Ex p i Ex t w strefach 2 i 22<\/li>\n<li>Wbudowany kalibrator<\/li>\n<li>Ekstraktor pierwiastkowy i liniaryzator<\/li>\n<li>Funkcja tarowania<\/li>\n<li>Opcjonalnie:\n<ul>\n<li>Pod\u015bwietlenie \u2013 mo\u017ce by\u0107 zasilane z p\u0119tli lub osobno<\/li>\n<li>Alarmy<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>Te wska\u017aniki zasilane p\u0119tl\u0105 posiadaj\u0105 certyfikacj\u0119 Ex ec i Ex tc przez stron\u0119 trzeci\u0105, co pozwala na ich instalacj\u0119 w panelach Ex e, Ex p lub Ex t w strefach 2 lub 22, bez potrzeby stosowania bariery lub izolatora galwanicznego, oraz bez uniewa\u017cniania certyfikacji obudowy panelowej. Oba modele posiadaj\u0105 wytrzyma\u0142e obudowy ze stali nierdzewnej oraz du\u017ce wy\u015bwietlacze o wysokim kontra\u015bcie i szerokim k\u0105cie widzenia, a tak\u017ce rozszerzony zakres temperatury pracy.<\/p>","protected":false},"featured_media":20463,"template":"","meta":{"_acf_changed":false},"product_cat":[54,98],"product_tag":[83,76,77],"class_list":["post-20032","product","type-product","status-publish","has-post-thumbnail","product_cat-wskazniki-wyswietlacze-beka-ex","product_cat-beka","product_tag-beka-associates","product_tag-front-ip66","product_tag-rear-ip20","tm-no-options-pxq","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/trautomatyka.com.pl\/en\/wp-json\/wp\/v2\/product\/20032","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/trautomatyka.com.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/trautomatyka.com.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/trautomatyka.com.pl\/en\/wp-json\/wp\/v2\/media\/20463"}],"wp:attachment":[{"href":"https:\/\/trautomatyka.com.pl\/en\/wp-json\/wp\/v2\/media?parent=20032"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/trautomatyka.com.pl\/en\/wp-json\/wp\/v2\/product_cat?post=20032"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/trautomatyka.com.pl\/en\/wp-json\/wp\/v2\/product_tag?post=20032"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}